{"id":4718,"date":"2026-11-03T10:58:59","date_gmt":"2026-11-03T09:58:59","guid":{"rendered":"https:\/\/www.aurelcz.eu\/kontakt-oder-kontaktlose-messung-wann-sollte-man-eine-taktile-sonde-und-wann-einen-optischen-scan-waehlen\/"},"modified":"2026-11-05T22:28:53","modified_gmt":"2026-11-05T21:28:53","slug":"contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning","status":"publish","type":"post","link":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/","title":{"rendered":"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">In automotive development, accurate component measurement is essential to the quality and reliability of the final product. Choosing a measurement method that suits the geometry, tolerances, material and required volume of data is equally important. Contact and non-contact 3D measurement methods are therefore not competitors in a simple battle between &#8216;old&#8217; and &#8216;new&#8217; technologies. Each method has its own indispensable role.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Touch Probes: Maximum Accuracy for Specific Points<\/span><\/h2>\n<p><b>Contact <\/b><a href=\"https:\/\/www.aurelcz.eu\/en\/3d-measurement-gain-accurate-results-that-give-you-a-competitive-edge\/\"><b>3D measurement<\/b><\/a><span style=\"font-weight: 400;\"> involves physical contact between a probe and the surface being measured. With coordinate measuring machines (CMMs), the individual points are subsequently used to evaluate the dimensions, shapes and positions of geometric features. The main advantage is <\/span><b>high accuracy.<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Depending on the equipment specifications and measurement conditions, high-end stationary CMMs can achieve accuracy in the order of a few micrometres. This makes contact measurement <\/span><b>a suitable choice for components with very tight tolerances<\/b><span style=\"font-weight: 400;\"> \u2013 for example, when inspecting holes, pins, mating surfaces and other functional geometric features, or when measuring gears, crankshafts and precision-machined components.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">However, physical contact also introduces <\/span><b>limitations<\/b><span style=\"font-weight: 400;\">. Contact measurement is performed point by point, and the time required to collect data increases with the number of points measured. For complex freeform surfaces, contact measurement can therefore be <\/span><b>significantly slower<\/b><span style=\"font-weight: 400;\"> than optical scanning. Physical contact is also unsuitable for very thin, soft or easily deformable components.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4584 size-large\" src=\"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-mereni-1024x550.jpg\" alt=\"\" width=\"1024\" height=\"550\" srcset=\"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-mereni-1024x550.jpg 1024w, https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-mereni-300x161.jpg 300w\" sizes=\"auto, (max-width:767px) 767px, (max-width:1024px) 100vw, 1024px\" \/><\/p>\n<h2><span style=\"font-weight: 400;\">Non-Contact Optical Scanning: A Faster Way to Capture the Entire Surface<\/span><\/h2>\n<p><b>Non-contact optical and laser scanners<\/b><span style=\"font-weight: 400;\"> capture surfaces without physical contact and can quickly generate a dense point cloud or a complete 3D surface model. Instead of selecting a few dozen or hundred points, the entire surface of a component can be captured and subsequently compared with its CAD model.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This is particularly useful when inspecting body panels, moulded plastic components or deformations following testing. Optical measurement is also suitable for flexible or sensitive surfaces because it does not exert any measurement force on them. However, the resulting accuracy depends on the scanner technology, component surface, calibration and measurement conditions. When assessing optical <\/span><b>3D measurement<\/b><span style=\"font-weight: 400;\">, it is therefore not enough to rely on a single accuracy specification \u2013 the specific system and application must be considered.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">When Should You Choose Each Method?<\/span><\/h2>\n<p><b>Contact 3D measurement<\/b><span style=\"font-weight: 400;\"> is appropriate when you need to verify a small number of critical dimensions with tight tolerances \u2013 such as a diameter, hole position or gear geometry accuracy. Conversely, if you need to capture the overall geometry of a component quickly, evaluate surface deviations or detect deformations, <\/span><b>non-contact optical scanning<\/b><span style=\"font-weight: 400;\"> will be more efficient.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Component size is another factor influencing the choice of measurement method. For smaller components requiring highly accurate measurement of specific dimensions and geometric tolerances, contact 3D measurement is generally more suitable. For larger components with complex geometries, where the shape and deviations across the entire surface need to be evaluated, optical scanning offers greater advantages. However, the choice of method also depends on the accessibility of the surfaces being measured, the required accuracy and the nature of the measurement task.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In practice, it is often unnecessary to choose just one approach. In fact<\/span><a href=\"https:\/\/www.aurelcz.eu\/en\/3d-measurement-is-indispensable-in-modern-vehicle-development-says-matus-frenak-from-aurel\/\"><span style=\"font-weight: 400;\">, <\/span><b>combining both methods can be the most effective solution<\/b><\/a><span style=\"font-weight: 400;\">: an optical 3D scan provides a rapid overview of the entire component, while a touch probe subsequently verifies critical features to the required higher level of accuracy. This combination of speed, comprehensive surface data and high accuracy makes it possible to adapt 3D measurement to the specific task \u2013 rather than the other way around.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-3521 aligncenter\" src=\"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/04\/fotogrametrie-1024x683.jpg\" alt=\"\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/04\/fotogrametrie-1024x683.jpg 1024w, https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/04\/fotogrametrie-300x200.jpg 300w\" sizes=\"auto, (max-width:767px) 767px, (max-width:1024px) 100vw, 1024px\" \/><\/p>\n<h2><span style=\"font-weight: 400;\">AUREL: Over 20 Years of Experience in 3D Measurement<\/span><\/h2>\n<p><a href=\"https:\/\/www.aurelcz.eu\/en\/\"><b>AUREL<\/b><\/a><span style=\"font-weight: 400;\"> has been specialising in 3D measurement for over 20 years. Today, its 3D metrology team comprises eleven specialists focusing on <\/span><b>static and dynamic <\/b><a href=\"https:\/\/www.aurelcz.eu\/en\/need-accurate-3d-measurement-without-the-risk-of-damage-try-photogrammetry\/\"><b>photogrammetry<\/b><\/a><b>, optical scanning and contact measurement.<\/b><span style=\"font-weight: 400;\"> Thanks to their wide-ranging expertise, the team can apply both traditional and highly sophisticated measurement techniques and respond flexibly to the specific requirements of each project. They also draw on their experience when collaborating with other companies within Colegium Holding, particularly <\/span><a href=\"https:\/\/www.lenam.cz\/en\/\"><b>LENAM<\/b><\/a><span style=\"font-weight: 400;\"> in the field of measurement.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Results That Support Decision-Making<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">For automotive manufacturers, the key consideration is the results and recommendations they receive from measurement. AUREL provides 3D colour deviation maps that clearly show the differences between a component&#8217;s actual geometry and its nominal CAD model, or between its condition before and after testing. These <\/span><a href=\"https:\/\/www.aurelcz.eu\/en\/virtual-modelling-and-cae-analyses-accelerate-development-and-reduce-costs\/\"><b>visualisations<\/b><\/a><span style=\"font-weight: 400;\"> are accompanied by tables containing precise values for dimensions, tolerances and other critical parameters.<\/span><\/p>\n<p><i><span style=\"font-weight: 400;\">\u201cIf customers need to work with the data further, we can also provide an STL model or a polygon mesh for use in CAD or metrology software. These results enable companies to determine immediately whether a component is within tolerance, whether tooling adjustments are required or whether intervention in the manufacturing process is necessary. This allows them to respond quickly and in good time, before more significant production losses occur,\u201d <\/span><\/i><span style=\"font-weight: 400;\">explains Mat\u00fa\u0161 Fren\u00e1k, Head of 3D Measurement and Road Safety Projects at AUREL.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In practice, the advantages of contact and non-contact measurement often complement each other. Choosing the right method depends on the characteristics of the component, the required accuracy and the purpose of the analysis. With extensive experience in both contact and non-contact measurement, AUREL can recommend <\/span><b>the most suitable approach for the specific requirements of each project<\/b><span style=\"font-weight: 400;\"> and deliver data that supports quality control and further technical decision-making.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/p>\n<p><b>Do you need to measure a component accurately or assess its deformation? <\/b><a href=\"https:\/\/www.aurelcz.eu\/en\/contact\/\"><b>Contact the AUREL experts<\/b><\/a><b> \u2013 together, we will find the most suitable solution for your project.<\/b><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In automotive development, accurate component measurement is essential to the quality and reliability of the final product. Choosing a measurement method that suits the geometry, tolerances,<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":9,"featured_media":4591,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[155],"tags":[],"class_list":["post-4718","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-measurement"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning - AUREL<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning - AUREL\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/\" \/>\n<meta property=\"og:site_name\" content=\"AUREL CZ s.r.o.\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/aurelcz.eu\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-03T09:58:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-05T21:28:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-merezni2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Zachovalova\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Zachovalova\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":[\"Article\",\"BlogPosting\"],\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/\"},\"author\":{\"name\":\"Zachovalova\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#\\\/schema\\\/person\\\/75d6961cc3c101a71c33cebd5fd3edf2\"},\"headline\":\"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning\",\"datePublished\":\"2026-11-03T09:58:59+00:00\",\"dateModified\":\"2026-11-05T21:28:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/\"},\"wordCount\":913,\"publisher\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aurelcz.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/3d-merezni2.jpg\",\"articleSection\":[\"Measurement\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/\",\"url\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/\",\"name\":\"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning - AUREL\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aurelcz.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/3d-merezni2.jpg\",\"datePublished\":\"2026-11-03T09:58:59+00:00\",\"dateModified\":\"2026-11-05T21:28:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.aurelcz.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/3d-merezni2.jpg\",\"contentUrl\":\"https:\\\/\\\/www.aurelcz.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/3d-merezni2.jpg\",\"width\":1920,\"height\":1280},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Dom\u016f\",\"item\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/\",\"name\":\"AUREL CZ s.r.o.\",\"description\":\"Partner pro v\u00fdvoj, v\u00fdrobu a inovace nejen v automobilov\u00e9m  pr\u016fmyslu\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#organization\",\"name\":\"AUREL CZ s.r.o.\",\"url\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aurelcz.eu\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/aurel-logo-112x112-1.png\",\"contentUrl\":\"https:\\\/\\\/www.aurelcz.eu\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/aurel-logo-112x112-1.png\",\"width\":112,\"height\":112,\"caption\":\"AUREL CZ s.r.o.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/aurelcz.eu\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/aurel-cz\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.aurelcz.eu\\\/en\\\/#\\\/schema\\\/person\\\/75d6961cc3c101a71c33cebd5fd3edf2\",\"name\":\"Zachovalova\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/51182d6618051b5d3731ba5f3e4adc0e7f8ee45d13b16285ec83b044f1cd4f9f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/51182d6618051b5d3731ba5f3e4adc0e7f8ee45d13b16285ec83b044f1cd4f9f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/51182d6618051b5d3731ba5f3e4adc0e7f8ee45d13b16285ec83b044f1cd4f9f?s=96&d=mm&r=g\",\"caption\":\"Zachovalova\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning - AUREL","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/","og_locale":"en_US","og_type":"article","og_title":"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning - AUREL","og_url":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/","og_site_name":"AUREL CZ s.r.o.","article_publisher":"https:\/\/www.facebook.com\/aurelcz.eu","article_published_time":"2026-11-03T09:58:59+00:00","article_modified_time":"2026-11-05T21:28:53+00:00","og_image":[{"width":1920,"height":1280,"url":"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-merezni2.jpg","type":"image\/jpeg"}],"author":"Zachovalova","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Zachovalova","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Article","BlogPosting"],"@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/#article","isPartOf":{"@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/"},"author":{"name":"Zachovalova","@id":"https:\/\/www.aurelcz.eu\/en\/#\/schema\/person\/75d6961cc3c101a71c33cebd5fd3edf2"},"headline":"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning","datePublished":"2026-11-03T09:58:59+00:00","dateModified":"2026-11-05T21:28:53+00:00","mainEntityOfPage":{"@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/"},"wordCount":913,"publisher":{"@id":"https:\/\/www.aurelcz.eu\/en\/#organization"},"image":{"@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-merezni2.jpg","articleSection":["Measurement"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/","url":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/","name":"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning - AUREL","isPartOf":{"@id":"https:\/\/www.aurelcz.eu\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/#primaryimage"},"image":{"@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-merezni2.jpg","datePublished":"2026-11-03T09:58:59+00:00","dateModified":"2026-11-05T21:28:53+00:00","breadcrumb":{"@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/#primaryimage","url":"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-merezni2.jpg","contentUrl":"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2026\/10\/3d-merezni2.jpg","width":1920,"height":1280},{"@type":"BreadcrumbList","@id":"https:\/\/www.aurelcz.eu\/en\/contact-or-non-contact-measurement-when-to-choose-a-touch-probe-and-when-to-use-optical-scanning\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Dom\u016f","item":"https:\/\/www.aurelcz.eu\/en\/"},{"@type":"ListItem","position":2,"name":"Contact or Non-Contact Measurement? When to Choose a Touch Probe and When to Use Optical Scanning"}]},{"@type":"WebSite","@id":"https:\/\/www.aurelcz.eu\/en\/#website","url":"https:\/\/www.aurelcz.eu\/en\/","name":"AUREL CZ s.r.o.","description":"Partner pro v\u00fdvoj, v\u00fdrobu a inovace nejen v automobilov\u00e9m  pr\u016fmyslu","publisher":{"@id":"https:\/\/www.aurelcz.eu\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aurelcz.eu\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.aurelcz.eu\/en\/#organization","name":"AUREL CZ s.r.o.","url":"https:\/\/www.aurelcz.eu\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aurelcz.eu\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2025\/06\/aurel-logo-112x112-1.png","contentUrl":"https:\/\/www.aurelcz.eu\/wp-content\/uploads\/2025\/06\/aurel-logo-112x112-1.png","width":112,"height":112,"caption":"AUREL CZ s.r.o."},"image":{"@id":"https:\/\/www.aurelcz.eu\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/aurelcz.eu","https:\/\/www.linkedin.com\/company\/aurel-cz\/"]},{"@type":"Person","@id":"https:\/\/www.aurelcz.eu\/en\/#\/schema\/person\/75d6961cc3c101a71c33cebd5fd3edf2","name":"Zachovalova","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/51182d6618051b5d3731ba5f3e4adc0e7f8ee45d13b16285ec83b044f1cd4f9f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/51182d6618051b5d3731ba5f3e4adc0e7f8ee45d13b16285ec83b044f1cd4f9f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/51182d6618051b5d3731ba5f3e4adc0e7f8ee45d13b16285ec83b044f1cd4f9f?s=96&d=mm&r=g","caption":"Zachovalova"}}]}},"_links":{"self":[{"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/posts\/4718","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/comments?post=4718"}],"version-history":[{"count":2,"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/posts\/4718\/revisions"}],"predecessor-version":[{"id":4720,"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/posts\/4718\/revisions\/4720"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/media\/4591"}],"wp:attachment":[{"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/media?parent=4718"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/categories?post=4718"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aurelcz.eu\/en\/wp-json\/wp\/v2\/tags?post=4718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}